HOME Construction Methods Fire resistant system Fire resistant structure (General fire resistant wall)

Fire resistant structure (60 minutes fire resistant partition walls, non-loadbearing)

General fire resistant wall
(1) Super Wall, Hyper Wall
By using regular hard-type gypsum board as the top layer board, excellent strength is realized. For fire resistant walls in places that require particularly high strength such as schools and hospitals.
Wall name 60 mins fire resistance
certification no.
Wall structure (horizontal sectional view)
Super Wall A FP060NP-0197
Hyper Wall 15Z FP060NP-0354
Hyper Wall Z FP060NP-0199
* Base layer is oriented like brick configuration.
Hyper Wall ZE FP060NP-0259

(2) A21, B15, S12, S12, S12 Gapped Spec
Standard models of fire resistant wall using fire resistant gypsum board "Tiger Board Type Z". For fire partitions.
Wall
name
60 mins fire resistance
certification no.
Wall structure (horizontal sectional view)
A21 FP060NP-0197
B15 FP060NP-0174
S12 FP060NP-0174
S12 -
Gapped
spec
FP060NP-0289
* Gapped parts are inserted with Tiger Joint Felt (partially treated with U Tight)

i3jGR-1AGR-2
Fire resistant wall systems using 8mm Tiger Glass Rock
Wall name 60 mins fire resistance
certification no.
Wall structure (horizontal sectional view)
GR-1 FP060NP-0221
GR-2 FP060NP-0219

i4jA60
Suitable for fire partition shafts that required to be constructed from only one side, such as lift shafts, stairwells, duct space, pipe space
Wall name 60 mins fire resistance certification no. Wall structure (horizontal sectional view)
A60 FP060NP-0258
* Joints are shifted 100mm or more between boards.