HOME „ Construction Methods „ Fire resistant system „ Fire resistant structure (S Wall)

Fire resistant structure (S Wall)

S Wall
We provide various types, starting with the base model of S Wall (Standard spec) that has a simple structure which formed by applying two layers of 21mm fire resistant gypsum board to one side of the framing.
[Recommended use location]
  • Suitable for areas required to be constructed from only one side, such as lift shafts, stairwells, duct space, pipe space
  • For constructing additional fire partition walls due to extension of buildings (can be installed on one side while also keeping the original wall)

[Features]
  • Simple structure: Two layers of 21mm fire resistant gypsum board are applied to one side of steel framing (Standard Spec)
  • Single-sided construction possible: No requirements for scaffold or work space on the other side of walls. Suitable for use as fire partition walls for shafts.
  • Flexible wall height adjustment: Wall height can be adjusted flexibly just by changing cross-section design of metal studs.

ƒS Wall - Standard spec„
Tape over joints of top layer of fire resistant gypsum board with glass fiber joint tape, and then apply both base coating and finish coating type of joint compounds over the tape to provide smooth surfaces.
[60 mins fire resistance certification no. FP060NP-0007]



ƒS Wall - Sealed joint spec„
This construction system has V grooved joints between top-layer of fire resistant gypsum board filled with urethane or deformed silicon sealant.
[60 mins fire resistance certification no. FP060NP-0049]




ƒS Wall - Extra layer spec„
This construction system requires no joint treatment for top-layer of gypsum boards and also provides crack resistance.
Please install this product by using method either a) or b) as follows.
a) Apply an additional layer of 9.5 mm Tiger Board with staples and adhesives to provide joints with gap (less than 6mm wide)
b) Apply an additional layer of decorated board (12.5mm thick) with double-sided tape and adhesives to provide joints with gap (less than 6mm wide)
[60 mins fire resistance certification no. FP060NP-0046]




ƒS Wall - Double-sided spec„
Joint treatment is made unnecessary by applying two layers of 21mm fire resistant gypsum board to one side and 12.5mm gypsum board to the other side.
[60 mins fire resistance certification no. FP060NP-0071]



ƒS Wall 65„Patented (Patent no.5363852)
Joint treatment is made unnecessary by treating the back of the joint of the top-layer fire resistant gypsum board with sealants.
[60 mins fire resistance certification no. FP060NP-0233]


* The base layer board surface (the surface that has no marking) is made to face the studs, and oriented like brick configuration.


ƒS Wall 100„
Joint treatment is made unnecessary by using Type 100 as its base framing.
[60 mins fire resistance certification no. FP060NP-0189]


* The base layer board surface (the surface that has no marking) is made to face the studs, and oriented like brick configuration.


ƒS Wall 100-i„
Joint treatment is made unnecessary by using Type 100 as its base framing.
Furthermore, by using square shaped studs, steady brace is also made unnecessary, making it possible to configure the base layer in grid orientation (uninterrupted seams).
[60 mins fire resistance certification no. FP060NP-0360]


Television commercials