HOMEConstruction Methodssound insulation wall method > Sound insulation wall with staggered stud framing (with sound absorbing material)

Sound insulation wall system with sound insulation performance equal to TLD-50
Sound insulation wall with staggered stud framing (with sound absorbing material)

Sound insulation performance is secured by staggered stud structure and sound absorbing material.
[Hyper Wall 15Z・WI]
Sound insulation performance (TLD) TLD-53
Sound insulation structure certification number SOI−0112
Fire resistant structure certification number FP060NP−0355 (60 minutes fire resistance: Non-loadbearing)
Recommended use location Separation wall between rooms in hotels and dormitories, especially places where hard surface is required.
Horizontal sectional view
  • ■Can also use rock wool as sound absorbing material in the cavity.
*Perimeter treatment is required. Non-loadbearing : Wall systems which do not bear building loads*Perimeter treatment is required. Non-loadbearing : Wall systems which do not bear building loads

[Hyper Wall Z・WI]
Sound insulation performance (TLD) TLD-52
Sound insulation structure certification number SOI−0112
Fire resistant structure certification number FP060NP−0200 (60 minutes fire resistance: Non-loadbearing)
Quality assurance law compliance certification number 1268 (Grade 3)
Recommended use location Separation wall between rooms in hotels and dormitories, especially places where hard surface is required.
Horizontal sectional view
  • ■Can also use rock wool as sound absorbing material in the cavity.
*Base layer is oriented like bricks, and perimeter treatment is required. Non-loadbearing : Wall systems which do not bear building loads

[B15・WI]
Sound insulation performance (TLD) TLD-49
Sound insulation structure certification number SOI−0110
Fire resistant structure certification number FP060NP−0175 (60 minutes fire resistance: Non-loadbearing)
Recommended use location Partition wall for in between rooms in dormitories and hotels.
Horizontal sectional view
  • ■Can also use rock wool as sound absorbing material in the cavity.
*Perimeter treatment is required. Non-loadbearing : Wall systems which do not bear building loads*Perimeter treatment is required. Non-loadbearing : Wall systems which do not bear building loads

[S12・WI]
Sound insulation performance (TLD) TLD-50
Sound insulation structure certification number SOI−0110
Fire resistant structure certification number FP060NP−0175 (60 minutes fire resistance: Non-loadbearing)
Recommended use location Partition wall for in between rooms in dormitories and hotels.
Horizontal sectional view
  • ■Can also use rock wool as sound absorbing material in the cavity.
*Perimeter treatment is required. Non-loadbearing : Wall systems which do not bear building loads*Perimeter treatment is required. Non-loadbearing : Wall systems which do not bear building loads