HOME / Construction methods / General wall construction methodSteel base

General wall construction method

Steel base
  • Non-wooden
  • Interior wall

Describes a general wall construction method using a steel base.

参考画像


General wall construction method_Steel base
公的認定等に関する表記
  • Construction (metal fittings)
    Items a. through d. explain the construction of metal fittings for standard walls. When constructing a structure to obtain a certification such as fire proof or resistant
    sound insulated etc.
    ensure that construction is in accordance with the certification specifications.
  • a.Gypsum board installation
    [1] When screwing onto a steel base
    use a screw of length at least 10mm longer than the board thickness
    and tighten the screw head so that it is slightly under the surface of the board.
    [2] The rules described in [1] also apply when overlaying by screwing upholstery board onto a steel base.
    [3] When overlaying a board on an underlaid board
    use adhesive and staples
    etc. together to attach the two.
  • b.Intervals between fasteners
    Screw: Surrounding area of approx. 200mm
    interval area of approx. 300mm
  • .Target screw lengths for single sheet layingfor single sheet laying
    Gypsum board thickness Screw length*
    ・9.5mm-20mm or more
    ・12.5mm-22mm or more
    ・15mm-25mm or more
    ・ 21mm-32mm or more
  • d. Target screw lengths for double sheet laying
    Gypsum board thickness Screw length
    ・9.5+9.5mm-28mm or more
    ・9.5+12.5mm-32mm or more
    ・9.5+15mm-38mm or more
    ・12.5+12.5mm-38mm or more
    ・12.5+15mm-38mm or more
    ・15+15mm-41mm or more
    ・15+21mm 51mm or more
    ・21+21mm 57mm or more
    *Indicates the length required to fix the overlay
  • Reference literature
    "Please refer to the following literature for details on [b. Intervals between fasteners]
    [c. Target screw lengths for single sheet laying]
    and [d. Target screw lengths for double sheet laying]. ・""Building Construction Standard Specifications and Comments JASS26 for Interior Work""
    Architectural Institute of Japan ・""Public Building Construction Standard Specifications"" overseen by the Ministry of Land
    Infrastructure
    Transport and Tourism Minister's Secretariat
    2013 edition"

GL4ヶ条

GLボンドの接着力を確保するために以下の「GL4ヶ条」を遵守してください。
(GL工法に必須の4ヶ条を1つでも省いた場合、剥離現象につながります)
  1. 【第1条】下地には必ずプライマーを塗布する

    プライマー(3倍液)を塗布することでGLボンドが下地に密着し、充分な接着力が得られます。

    ※プライマー・・・スーパータックRもしくはスーパータックA
    GL4ヶ条参考画像
  2. 【第2条】下こすり、コテ圧は充分に!

    プライマー(3倍液)を塗布することでGLボンドが下地に密着し、充分な接着力が得られます。

    GL4ヶ条参考画像
  3. 【第3条】ダンゴサイズ(塗布量)は充分に!

    1回に塗り付けるボリュームを減らすと、接着力を発揮する有効面積が少なくなり、剥離現象につながり危険です。

    GL4ヶ条参考画像
  4. 【第4条】塗り付けピッチを守る

    タイガーボード(910×1820㎜)に43個以上のGLボンドのダンゴが付きます。塗り付けピッチを広げると、接着面積が少なくなり、接着力が確保できず、剥離することがあります。