Sound insulation performance standard according to the Architectural Institute of Japan
HOME ⁄ Why block sound? “Sound insulation” ⁄ Sound insulation performance ⁄ Sound insulation performance standard according to the Architectural Institute of Japan
Sound insulation performance standard according to the Architectural Institute of Japan
Building | Room purpose | Part | Application grade | |||
---|---|---|---|---|---|---|
Special grade (Especially excellent) |
Grade 1 (Excellent) |
Grade 2 (Standard) |
Grade 3 (Slightly inferior) |
|||
Multiple dwelling complex (Apartment/Condo) | Living space | Separation wall between adjacent units | D-55 | D-50 | D-45 | D-40 |
Hotel | Guest room | Separation wall between guest rooms | D-55 | D-50 | D-45 | D-40 |
Office | Room requiring privacy in business | Partition wall between rooms Separation wall between tenants |
D-50 | D-45 | D-40 | D-35 |
Schools | Regular classroom | Partition wall between rooms | D-45 | D-40 | D-35 | D-30 |
Hospital | Hospital room (individual room) | 〃 | D-50 | D-45 | D-40 | D-35 |